Application

Fully tight lead-through of pipes, ducts and cables in roofs, walls and storey partitions

By clicking on the illustration below and moving the pointer to the numbers, further information will appear.

Fast, easy and reliable lead-through – outside and inside

PERFORM membrane bushing LIGHT – adhesive solution for the completely sealed bushing of pipes, ducts and cables with diameters of up to 350 mm. The membrane bushing complies with the Danish Building Regulations' new requirements and can be used for bushing in...

  • damp coursing
  • underroof with various breadth products
  • permanent underroof
  • wall
  • floors with wood and iron beam layers

Download brochure:

PDF

Product data and accessories

PERFORM membrane bushings LIGHT are made of a special two-component flexible rubber membrane. The membrane bushing LIGHT is fitted with adhesive tape along all edges, and can be mounted on most building materials. The bushings come in five different sizes for pipes up to Ø 350 mm.

Overview
VVS-no.Max pipe sizeW x L
288070100 Ø 100 mm 200 x 200
288070125 Ø 125 mm 250 x 250
288070160 Ø 160 mm 300 x 300
288070250 Ø 250 mm 400 x 400
288070350 Ø 350 mm 500 x 500

Overview with hole

VVS-no.Hole sizePipe sizeW x L
288072100 Ø80 Ø 100 mm 200 x 200
288072125 Ø100 Ø 125 mm 250 x 250
288072160 Ø128 Ø 160 mm 300 x 300
288072250 Ø200 Ø 250 mm 400 x 400
288072350 Ø280 Ø 350 mm 500 x 500

 

Accessories
ProductVVS no.
PERFORM Adhesive tape 8m x 20mm x 1mm, grey 288069120
PERFORM Adhesive 290 ml, black 288059529

 

Technical datasheet for PERFORM Adhesive Safetysheets for PERFORM Adhesive

Fixing Instructions

Prior to installation

The following three steps apply to any project in which you are sealing with PERFORM membrane bushing LIGHT. Follow these steps. Further details applicable to specific projects can be found below and overleaf.

1. Make sure that you are able to cover the whole of the pipe hole with the seal. Ensure that the surface is free of dust etc.

2. Cut the hole in the membrane bushing approx. 20% smaller than the pipe diameter.

3. Ensure that the back of the membrane is clean, dry and free of grease and dust. Apply the adhesive evenly over the back of the membrane before passing it over the pipe, duct or cable.

Mounting

For installation, always use PERFORM adhesive on the back of the membrane bushing LIGHT. When installing on a storey partition, a ridge or on a roof with a solid underroof, the PERFORM membrane bushing can also be secured with screws for additional sealing security.

How to install PERFORM membrane bushing LIGHT

Wall

1. Clean the surface of the vapour barrier or wind barrier thoroughly.

2. Pass the membrane bushing over the pipe, and press it securely into place on the wall.

3. Ensure that the membrane bushing seals tightly around the pipe.

4. After installation, carry out jointing where the pipe meets the membrane.

Vapour barrier/wind barrier

Storey partition

1. Clean the surface of the storey partition thoroughly.

2. Pass the membrane bushing over the pipe, and press it securely into place on the storey partition.

3. Screw the membrane bushing to the storey partition through the holes, if required.

4. Ensure that the membrane bushing seals tightly around the pipe.

5. After installation, carry out jointing where the pipe meets the membrane.

Concrete deck, wood or steel

Roof – ridge

1. Bend the membrane bushing in the middle to align the angle to the roof.

2. Adjust the top batten to allow plenty of space for installation.

3. Pass the membrane bushing over the pipe, and press it firmly down onto the underroof.

4. Screw the membrane bushing to the underroof, if required.

5. Ensure that the membrane bushing seals tightly around the pipe.

6. After installation, carry out jointing where the pipe meets the membrane.

Through ridge

Roof – sheets

1. Secure a plate under the sheet – as underlay for the membrane bushing.

2. Clean the surface of the underroof and stretch the foil well around the pipe.

3. Pass the membrane bushing over the pipe, and press it firmly down onto the underroof.

4. Ensure that the membrane bushing seals tightly around the pipe.

5. After installation, carry out jointing where the pipe meets the membrane.

Underroof of sheets

Roof – solid

1. Pass the membrane bushing over the pipe, and press it firmly down onto the underroof.

2. Screw the membrane bushing to the underroof though the holes, if required.

3. Ensure that the membrane bushing seals tightly around the pipe.

4. After installation, carry out jointing where the pipe meets the membrane.

Solid underroof

Roof – solid/felt

1. Pass the membrane bushing over the pipe, and press it firmly down onto the underroof.

2. Screw the membrane bushing to the underroof though the holes, if required.

3. Ensure that the membrane bushing seals tightly around the pipe.

4. Burn the roofing felt directly onto the metal frame of the membrane bushing.

5. After installation, carry out jointing where the pipe meets the membrane.

Solid underroof with roofing felt